彩票走势图

Multifunctional water pump control valve

PRODUCTS > Hydraulic control valve > Multifunctional water pump control valve

Multifunctional water pump control valve

Product model: JD745X
Product specification: DN40-DN1600
Nominal pressure: 1.6MPa-2.5MPa
Connection: flange type
Applicable medium: water
Medium temperature: 0℃~80℃
Body material: cast iron, cast steel, carbon steel, stainless steel
shared:

[Essential information]

Multifunctional pump control valve from the main valve and the valve body and take over the system components, DC type valve, the main valve control room control room for double diaphragm or piston structure, the control room than the average increase of the hydraulic control valve a, increases the control function of the main valve, the water pump outlet slowly open, open, slow closing, closing and other multi-functional control, achieved the function of a valve, a regulator on the pump export control.

The control system of the multi-function pump control valve adopts the control valve. By setting the opening of the regulating valve, various control parameters can be conveniently realized, such as the opening speed of the main valve, the speed of slow closing and so on. When the water pump starts, the water pressure acts on the main valve, the valve plate and the lower chamber of the control chamber. This pressure causes the main valve to be opened. The water in the upper chamber of the control chamber is slowly discharged to the outlet through the regulating valve B, and the main valve is opened slowly. Setting the opening of the regulating valve, you can get the proper opening speed of the main valve. When the pump stops working after the inlet pressure decreases rapidly, quickly shut down most of opening under the action of self weight, spring pressure, prevent water backflow opening remaining from the control room on cavity pressure and water pressure of the lower cavity under the combined effect of slowly closing, slowing the closing speed of forming a buffer, to prevent the pressure surge.


[Manufacturing standards]

Quality ensureISO9000
Design standardCJ/T219
Structural lengthGB/T12221
Flange standardGB/T 17241.6  GB/T 9113
Test standardGB/T 13927 API 598


[Valve features]
1, A, B set the valve opening and the opening ratio of the right valve opening and closing speed. To prevent water hammer good, will slow open, check back, fast closing, slow closing and so on to eliminate water hammer technical integration, to prevent the pump does not hammer and stop pumping back and water hammer on the water supply pipeline and pump damage.

2, easy to operate, no need for the valve with electrical control system, the valve with the pump on and off, automatically and sequentially complete control functions. The proper control parameters can be obtained by setting the opening of the regulating valve.

3 、 the valve body adopts full passage, direct current and streamline design. The utility model has the advantages of small hydraulic loss and good energy saving effect. The valve is installed at the outlet of the water pump, in order to realize the functions of slow opening, full opening, quick closing, slow closing and so on.

1, pool
2, elastic seat sealing gate valve
3, filter
4, Water pump
5, multifunctional water pump control valve
6, elastic seat sealing gate valve


Main outline dimensions

DNLHDD1n-d
1.0MPa1.6MPa2.5MPa1.0MPa1.6MPa2 5MPa1.0MPa1.6MPa2 5MPa
502002931651651651251251254-184-184-18
652103281851851851451451454-184-188-18
802353642002002001601601608-188-188-18
1002754182202202351801801908-188-188-22
1253104812502502702102102208-188-188-22
1503455432852853002402402508-228-228-26
2004156733403403602952953108-2212-228-26
25048579239540542535035537012-2212-2612-26
30054092744546048540041043012-2212-2612-30
35059595750552055546047049016-2216-2616-30
400655118856558062051552555016-2616-3016-33
450710121861564067056558560020-2620-3016-36
500760125667071573062065066020-2620-3320-36
6008501600780840
725770
20-3020-3620-36
7009501750895910
840840
24-3024-36
8001120190010151025
950950
24-3324-39
900122021001115

1050

28-33

1000132024001230

1160

28-36


[Adaptive condition]

       Water control valve is the pipe medium pressure as the driving force for opening and closing, regulating valve. It consists of a main valve and attached to the catheter and needle valve, ball valve and pressure gauge, etc. according to the purpose and function of the different places, can be turned into a remote control float valve, relief valve, relief valve closed, flow controller, pressure relief valves, hydraulic control valves, emergency shut down valve.

Hydraulic control valve action:
1, It can be used in domestic water supply, fire fighting system and industrial water supply system.
2, hydraulic control valve to use the pilot valve to control the opening and closing of the valve, saving energy.
3, can replace other valves, large electric device.
4, hydraulic control valve products are widely used in high-rise buildings, living areas and other water supply network systems and urban water supply projects.